Riveting and clinching series Hex base / Cylindrical base

Grounding clinch studs

MaterialCarbon steel / stainless steelRivet thickness0.5mm ~ 4mmMounting methodClinching

Product description

Compiled from the existing technical description of this product on this site

The grounding clinch stud is designed for sheet-metal grounding and is firmly installed in the panel by clinching, providing a reliable electrical connection point with low contact resistance. Compact and easy to install, it does not rotate after clinching, keeping the grounding path electrically continuous over the long term while also providing mechanical support strength.

Technical Features
Clinch-fixed, non-rotating and non-loosening for a stable grounding connectionLow contact resistance ensures electrical continuityNo welding; sheet plating and appearance remain intactProvides an external-thread connection point that can also carry structural fixingCarbon steel / stainless steel optional; stainless steel better suits corrosion-protection requirements
Applications
Enclosure and cabinet groundingElectrical equipment housingsEnergy storage and distribution cabinetsTelecom base station cabinets

Specifications

The parameters listed on this page are subject to final inspection and the applicable standards; items not listed follow the customer drawing or the order agreement and are not committed by default.

Material Carbon steel / stainless steel
Head type Hex base / cylindrical base (by model)
Mounting method Clinching
Rivet thickness 0.5mm ~ 4mm (by model)
Surface treatment Zinc plated / Dacromet / Plain
Standard Clinch / blind-rivet structure per customer drawing / corporate standard; threads GB/T 196, GB/T 197 (ISO 965-1); mechanical properties and mounting-hole dimensions per the manufacturer's datasheet (e.g. PEM system)

Spec lookup

Based on your operating conditions, look up directly among the 15 models in this series — pure front-end filtering, no redirects, no URL changes

Filter results are based on the specification fields published on each model page and are for preliminary screening only; the final selection must be confirmed in light of the actual load, plate thickness and assembly process.

Drawings and documentation

Official catalogues and manuals are available for direct download; custom drawings are handled per project

PDF

Rivet Nut Product Manual

Specifications, installation and performance data 4.6 MB

Download

Manufacturing process

The usual process route for this product family; actual operations follow the drawing and order requirements.

  • Cold heading / TurningSleeve body and flange formed in one step
  • Tapping and deformation-zone machiningInternal thread and riveting deformation zone
  • Heat treatmentTreated to material and strength requirements
  • Surface treatmentZinc plated / Dacromet / Plain
  • Spot checks of riveting performanceVerified pull-out force, shear strength and rivet thickness

Capacity & delivery

Taken from the company's published capacity and certification information; no unverified claims are included.

6.5100M pcs/monthCombined monthly capacity of the Shenzhen and Xiangyang (Hubei) dual bases
As fast as 1-day prototypingFast prototyping channel after drawing or sample confirmation
26patentsPatents for fastening structures and assembly processes
3system certificationsIATF 16949 / ISO 9001 / ISO 14001

FAQ

Material, standards, surface treatment and installation points for this model; the data comes from the specification table on this page and from the national standards cited in the answers.

Q1What material is used for "Grounding clinch stud (low contact resistance, ensuring electrical continuity)"? What strength level does it achieve?

Specified in the specification table on this page: material carbon steel / stainless steel. A material certificate and mechanical property test report can be provided with the goods; batch acceptance is carried out in accordance with the above specifications.

Q2What is the head type, drive and structure of "Grounding clinch stud (low contact resistance, ensuring electrical continuity)"?

The specification table on this page notes: head types are hex base / cylindrical base (by model). Structural details are subject to the drawing.

Q3What are the main features of "Grounding clinch stud (low contact resistance, ensuring electrical continuity)"?

Features listed in the product description on this page: clinch fixing, no rotation or loosening, stable grounding connection; low contact resistance, ensuring electrical continuity; no welding, no damage to the sheet coating or appearance; provides an external-thread connection point that can also carry structural fixing.

Q4To what standards is "Grounding clinch stud (low contact resistance, ensuring electrical continuity)" manufactured and accepted?

Standards noted in the specification table on this page: clinch/blind-rivet structure per customer drawing / corporate standard; threads to GB/T 196 and GB/T 197 (ISO 965-1); mechanical properties and mounting-hole dimensions per the manufacturer's datasheet. Dimensional inspection reports can be supplied with the goods; batch acceptance follows the above standards and the drawings agreed by both parties.

Q5Can "Grounding clinch stud (low contact resistance, ensuring electrical continuity)" be used on aluminium sheet and other dissimilar metals?

Selection to requirements is possible, but contact between steel parts and aluminium sheet, or between dissimilar metals in humid environments, tends to cause galvanic corrosion. The usual practice is zinc plating or Dacromet coating to improve corrosion resistance, verified in critical applications by salt-spray testing to GB/T 10125 and under actual service conditions. (Applies to the model “grounding clinch stud (low contact resistance, ensuring electrical continuity)”.)