Riveting and clinching series Hex base / Cylindrical base
Grounding clinch studs
Product photos
Actual photos, not renders

Illustration note
The image shows an actual part of this specification; appearance differs with surface treatment and head style, and the delivered part prevails.
Images are for appearance and structure reference; dimensions and tolerances are subject to the specifications and the applicable standards on this page.
Product description
Compiled from the existing technical description of this product on this site
The grounding clinch stud is designed for sheet-metal grounding and is firmly installed in the panel by clinching, providing a reliable electrical connection point with low contact resistance. Compact and easy to install, it does not rotate after clinching, keeping the grounding path electrically continuous over the long term while also providing mechanical support strength.
Specifications
The parameters listed on this page are subject to final inspection and the applicable standards; items not listed follow the customer drawing or the order agreement and are not committed by default.
| Material | Carbon steel / stainless steel |
|---|---|
| Head type | Hex base / cylindrical base (by model) |
| Mounting method | Clinching |
| Rivet thickness | 0.5mm ~ 4mm (by model) |
| Surface treatment | Zinc plated / Dacromet / Plain |
| Standard | Clinch / blind-rivet structure per customer drawing / corporate standard; threads GB/T 196, GB/T 197 (ISO 965-1); mechanical properties and mounting-hole dimensions per the manufacturer's datasheet (e.g. PEM system) |
Spec lookup
Based on your operating conditions, look up directly among the 15 models in this series — pure front-end filtering, no redirects, no URL changes
Filter results are based on the specification fields published on each model page and are for preliminary screening only; the final selection must be confirmed in light of the actual load, plate thickness and assembly process.
Drawings and documentation
Official catalogues and manuals are available for direct download; custom drawings are handled per project
Rivet Nut Product Manual
Specifications, installation and performance data 4.6 MB
Manufacturing process
The usual process route for this product family; actual operations follow the drawing and order requirements.
- Cold heading / TurningSleeve body and flange formed in one step
- Tapping and deformation-zone machiningInternal thread and riveting deformation zone
- Heat treatmentTreated to material and strength requirements
- Surface treatmentZinc plated / Dacromet / Plain
- Spot checks of riveting performanceVerified pull-out force, shear strength and rivet thickness
Capacity & delivery
Taken from the company's published capacity and certification information; no unverified claims are included.
FAQ
Material, standards, surface treatment and installation points for this model; the data comes from the specification table on this page and from the national standards cited in the answers.
Q1What material is used for "Grounding clinch stud (low contact resistance, ensuring electrical continuity)"? What strength level does it achieve?
Specified in the specification table on this page: material carbon steel / stainless steel. A material certificate and mechanical property test report can be provided with the goods; batch acceptance is carried out in accordance with the above specifications.
Q2What is the head type, drive and structure of "Grounding clinch stud (low contact resistance, ensuring electrical continuity)"?
The specification table on this page notes: head types are hex base / cylindrical base (by model). Structural details are subject to the drawing.
Q3What are the main features of "Grounding clinch stud (low contact resistance, ensuring electrical continuity)"?
Features listed in the product description on this page: clinch fixing, no rotation or loosening, stable grounding connection; low contact resistance, ensuring electrical continuity; no welding, no damage to the sheet coating or appearance; provides an external-thread connection point that can also carry structural fixing.
Q4To what standards is "Grounding clinch stud (low contact resistance, ensuring electrical continuity)" manufactured and accepted?
Standards noted in the specification table on this page: clinch/blind-rivet structure per customer drawing / corporate standard; threads to GB/T 196 and GB/T 197 (ISO 965-1); mechanical properties and mounting-hole dimensions per the manufacturer's datasheet. Dimensional inspection reports can be supplied with the goods; batch acceptance follows the above standards and the drawings agreed by both parties.
Q5Can "Grounding clinch stud (low contact resistance, ensuring electrical continuity)" be used on aluminium sheet and other dissimilar metals?
Selection to requirements is possible, but contact between steel parts and aluminium sheet, or between dissimilar metals in humid environments, tends to cause galvanic corrosion. The usual practice is zinc plating or Dacromet coating to improve corrosion resistance, verified in critical applications by salt-spray testing to GB/T 10125 and under actual service conditions. (Applies to the model “grounding clinch stud (low contact resistance, ensuring electrical continuity)”.)